... stability bracing when the scaffold height exceeds three (3) times the minimum base width. a. 1) After securing the first tie-in at an elevation of four times the minimum base, two separate requirements are given for the next interval up. a. If the scaffold is wider than 3', subsequent tie-ins must...
Proceedings Papers

Paper presented at the ASSE Professional Development Conference and Exposition, June 11–14, 2006
Paper Number: ASSE-06-735
... tie-ins must be secured to the building or structure at intervals no greater than 26 feet vertically. b. If the scaffold is less than 3' wide, the subsequent tie-ins must be at no greater than 20' maximum vertical intervals. 2) Ties should be placed as close as possible to the top of the scaffold...