Synopsis

Since there is no published work on the slippage characteristics of positive displacement liquid meters and, since such information is needed by meter operators, the author has undertaken a special meter testing project at East Chicago to furnish information. He describes the procedure used to make a large number of tests on small size meters. Laboratory results tend to prove that slippage errors are of considerable magnitude and follow definite patterns of viscosity vs. head loss relationship. Limited field tests indicate slippage characteristics of larga meters follow a definite pattern similar to that shown for small meters tested in the laboratory.

It is concluded that it is possible to obtain accurate readings from a displacement meter without making test runs each time viscosity or head loss changes. By proper use of this information more economical methods for the operation of pipe line meters may be developed.

Résumé

Etant donné qu'il n'existe aucun travail publié sur les caractéristiques du décalage des compteurs volumétriques et que les utilisateurs de ces compteurs ont besoin d'informations en ce sens, l'auteur a entrepris à East Chicago un travail en vue de fournir ces renseignements. I1 décrit la méthode utilisée pour faire un grand nombre d'essais sur des compteurs de petites dimensions. Les résultats obtenus en laboratoire tendent à prouver que les erreurs de décalage sont d'une étendue considérable et obéissent à une relation déterminée entre la viscosité et la perte de charge.

Des essais - en nombre limités effectués sur le terrain révèlent que les caractéristiques de décalage Shell Oil Company, Products Pipe Line Dept., East Chicago, Ind. U.S.A. des gros compteurs obéissent à des relations semblables à celles trouvées pour les petits compteurs étudiés au laboratoire.

En conclusion, il est possible d'obtenir des données exactes d'un compteur volumétrique sans faire l'étalonnage de l'appareil pour toute modification de viscosité ou de perte de charge. Un usage judicieux de ces renseignements peut permettre une utilisation plus économiques des compteurs pour pipe lines.

Introduction

This paper constitutes a report of investigations being carried on for a twofold purpose. First, we wish to determine the exact slippage characteristics of Positive Displacement meters operating on petroleum products pipe lines; and second, we wish to devise a better means for handling this troublesome error in pipe line metering.

Positive displacement meters of the capillary sealed type have been used on our products pipe line system during the past twelve years for the measurement of liquid petroleum products. Size 4" and size 6" meters are used on the pipe line proper with pressures up to 1200 psi. Size 4" meters are used at truck loading racks and terminal take-off points with pressures up

This content is only available via PDF.