1-15 of 15
Keywords: ksi
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 3–7, 2024
Paper Number: AMPP-2024-20780
... (ASS), especially UNS S31603 with a minimum yield strength (YS) of 170 MPa (25 ksi), is frequently used for hydrogen applications due to its low susceptibility to HE compared with other ASSs. However, ASS cannot be used when high strength (YS > 500 MPa) is required. Nitrogen-strengthened (e.g. UNS...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 3–7, 2024
Paper Number: AMPP-2024-20880
... Sample ID Sa 3 Flash Rust Medium Flash Rust Heavy St 2 Moist Sa 3 Adhesion 9.3 MPa (1.35 ksi) 10.7 MPa (1.55 ksi) 11.1 MPa (1.61 ksi) 9.7 MPa (1.41 ksi) 13.6 MPa (1.97 ksi) Fracture 100% B 100% B 100% B 100% B 20% B 80% C Adhesion 10.1 MPa (1.46 ksi) 11.1 MPa (1.61 ksi) 11.3 MPa (1.64 ksi) 7.9 MPa (1.15...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 3–7, 2024
Paper Number: AMPP-2024-20858
... ABSTRACT In order to extend the range of alloy 955 (UNS N09955) applications, the manufacturing process of this alloy has been further optimized to increase its ductility, toughness and, more importantly, resistance to hydrogen embrittlement and still provide 827 MPa (120 ksi) as minimum yield...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 3–7, 2024
Paper Number: AMPP-2024-20989
... scenarios are computed. In all modeling cases fatigue fracture failure is defined at the middle of the crack front when either K1c (28 ksi in0.5, plain strain fracture toughness) or K1e (38 ksi in0.5, fracture toughness for surface crack) are exceeded. Stress Analysis To first understand the stress field...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 3–7, 2024
Paper Number: AMPP-2024-20618
... tests in sour water environment showed that FCGR increased with decreasing load frequency, particularly with high K (32 ksi· in or 35 MPa· m ). When K was between 12 ksi· in (13MPa· m) and 36 ksi· in (40 MPa· m), FCGR of all specimens in sour water are higher than the mean + 2 SD (Standard Deviation...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 19–23, 2023
Paper Number: AMPP-2023-19273
... by UNS S41425, S41426 and S41427 with specified minimum yield strengths (SMYS) between 95 ksi (655 MPa) to 125 ksi (758 MPa).4 These grades show a good compromise between mechanical properties and corrosion resistance, and good sulfide stress cracking resistance. Super 13Cr are widely used in oil and gas...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 19–23, 2023
Paper Number: AMPP-2023-19269
... yield strength (YS) of 25 ksi (170 MPa), is frequently used for hydrogen applications due to its low susceptibility to HE, which is promoted by a high austenite stability. However, its use is limited when higher strength is required. Here, nitrogenstrengthened (UNS S20910), CrMnN and high interstitial...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 19–23, 2023
Paper Number: AMPP-2023-19291
... publication association air 1000 embrittlement rights permission ksi ht 0 production chemistry materials and corrosion flowline corrosion hollow sample 34 performance mpa alloy effect Paper No. 19291 MARCH 19-23, 2023 | DENVER, COLORADO Elevated Temperature Effects of Hydrogen and Hydrogen...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 19–23, 2023
Paper Number: AMPP-2023-19327
... on substrates treated by different surface treatment methods Surface treatment Sa 2 ½ WJ-2L FRP A FRP B FRP C Pull-off adhesion coating system 1 Adhesion Fracture 9.8 MPa (1.4 ksi) 12.1 MPa (1.8 ksi) 14.3 MPa (2.1 ksi) 13.0 MPa (1.9 ksi) 16.0 MPa (2.3 ksi) Y/Z Y/Z B/C B/C B/C Pull-off adhesion system 2 Adhesion...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 19–23, 2023
Paper Number: AMPP-2023-19429
... frequency on the fatigue crack growth rates (FCGRs) of AISI 4340 in the 180 ksi (1241 MPa) condition to determine an appropriate knockdown factor for lifing and integrity of a critical offshore component. A frequency scan at a relatively high cyclic crack driving force (ΔK = 36 ksi√in. (39.6 MPa√m) and R...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 19–23, 2023
Paper Number: AMPP-2023-19173
... examination fillet weld association weld rights upstream oil & gas materials and corrosion repad permission performance ksi strength nozzle crack responsibility publication cross-section intergranular Paper No. 19173 MARCH 19-23, 2023 | DENVER, COLORADO Intergranular Stress Corrosion...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 6–10, 2022
Paper Number: AMPP-2022-17648
... their yield strength at room temperature (> 345 MPa (50 ksi)). The tensile strength of UNS S20910 can be further increased by cold-working, which makes the material more versatile. This paper discusses the influence of strain hardening on the mechanical and corrosion properties of UNS S20910. The corrosion...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 6–10, 2022
Paper Number: AMPP-2022-17720
... to increase the yield strength of UNS N08034 to values higher than 120 ksi (827 MPa). In this study, a manufacturing process was developed based on thermodynamic and laboratory studies and subsequently applied to mill production trials. This paper reports the results from mechanical testing as well...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 6–10, 2022
Paper Number: AMPP-2022-17966
... environments, tube products manufactured in high quality corrosion resistant alloys (CRAs) are required. Recently, cold worked UNS N06985 tubes have been developed and produced for OCTG in specified minimum yield strength 110 ksi and 125 ksi in two dimensions. Laboratory testing has provided mechanical...
Proceedings Papers

Paper presented at the AMPP Annual Conference + Expo, March 6–10, 2022
Paper Number: AMPP-2022-17840
... subsurface corrosion h2s management upstream oil & gas water quench material protection responsibility annealed condition oilfield chemistry well integrity corrosion management retrieval system grade 29 application materials and corrosion riser corrosion renewable energy ksi alloy...